Project Review Comments
- Project Name
- Sand Creek Channel Design CDs
- Description
- Sand Creek Channel Design Report end to end; Overall Bank / Channel Stabilization Plans 30 percent design concept from South Sterling Ranch Dev to Retreat at TimberRidge S. border.
- Location
- Applicant
-
JR Engineering
Glenn Ellis ( gellis@jrengineering.com )
(303) 267-6241 Glenn Ellis ( gellis@jrengineering.com )
(303) 267-6241 - EA Number
- 17-87
- File Number
- CDR204
- Project Manager
- Kari Parsons
- Status
- Active
- Created
- 4/18/2019 2:42:49 PM
View: Project Documents
Agency | Comment | ||
---|---|---|---|
County Attorney - Development Review
7/3/2024 12:46:35 PM |
This Detention Maintenance Agreement does not appear to be the one we've been working on for the channel. It is written to accompany Sterling Ranch East Filing 3. Please clarify. | 7/3/2024 12:46:35 PM | |
PCD Engineering Division
7/3/2024 11:57:05 AM |
See previous comments. The agreement submitted is for a different project. -- Jeff Rice - 719-520-7877 |
7/3/2024 11:57:05 AM | |
EPC Stormwater Review
4/17/2024 6:37:56 AM |
EPC DPW Stormwater does not have any additional comments. Reviewed by: Christina Prete, P.E. Stormwater Manager ChristinaPrete@elpasoco.com |
4/17/2024 6:37:56 AM | |
View |
PCD Engineering Division
4/17/2024 2:15:07 PM |
See comment letter (link to left) and redlines. Note that FDR comments # 5 and #9 require additional discussion in regard to maintenance provisions and the maintenance agreement. One remaining comment can be addressed in the applicable memo or an additional memo. The following items need to be revised and resubmitted: - Channel maintenance agreement with Exhibits, when available. Staff will send revisions when available. - Other items highlighted in blue on the engineering checklist need to be provided when available, with signatures where applicable. Note: the following condition is proposed for the final design report: "See design support memos #1 and #2. Sterling Ranch Metropolitan District shall actively manage the areas of concern for vegetation and stability under a County-approved adaptive management plan and monitoring program in conjunction with the updated channel maintenance agreement." -- Jeff Rice - 719-520-7877 |
4/17/2024 2:15:07 PM |
Colorado Springs Public Works
4/15/2024 8:11:39 AM |
Engineering Development Review has no comment on this item. Joel Dagnillo, P.E. Engineer III Engineering Development Review City of Colorado Springs (719)385-5412 Joel.dagnillo@coloradosprings.gov |
4/15/2024 8:11:39 AM | |
Colorado Springs Public Works
3/28/2024 10:56:50 AM |
Traffic Engineering has no comments on this item. Zaker Alazzeh, P.E. Traffic Engineering Manager/Deputy City Traffic Engineer City of Colorado Springs (719) 385-5468 Zaker.Alazzeh@coloradosprings.gov |
3/28/2024 10:56:50 AM | |
View |
PCD Engineering Division
1/17/2024 5:37:14 PM |
(CDs-Part 4 redlined pages) | 1/17/2024 5:37:14 PM |
View |
PCD Engineering Division
1/17/2024 5:33:05 PM |
(CDs-Part 1 redlines) | 1/17/2024 5:33:05 PM |
View |
PCD Engineering Division
1/17/2024 3:14:00 PM |
See comment letter (link to left) and redlines. Note that FDR comments # 5 and #9 require additional discussion in regard to maintenance provisions. The following items need to be revised and resubmitted: - CDs/GEC Plan (parts 1 and 3) - Channel maintenance agreement or proposed revisions for concurrence. - Other items highlighted in blue on the Engineering checklist need to be provided when available, with signatures where applicable. Note: the following condition is proposed for the final design report: "See design support memos #1 and #2. Sterling Ranch Metropolitan District shall actively manage the areas of concern for vegetation and stability under a County-approved adaptive management plan and monitoring program in conjunction with the updated channel maintenance agreement." -- Jeff Rice - 719-520-7877 |
1/17/2024 3:14:00 PM |
EPC Stormwater Review
1/16/2024 9:21:18 AM |
EPC DPW Stormwater does not have any additional comments. Reviewed by: Christina Prete, P.E. Stormwater Engineer III ChristinaPrete@elpasoco.com |
1/16/2024 9:21:18 AM | |
View |
PCD Engineering Division
9/12/2023 1:27:44 PM |
(FAE redlines) | 9/12/2023 1:27:44 PM |
View |
PCD Engineering Division
9/12/2023 1:26:51 PM |
(CDs-Structural page) | 9/12/2023 1:26:51 PM |
View |
PCD Engineering Division
9/12/2023 1:13:17 PM |
(CDs Part 3 redlines) | 9/12/2023 1:13:17 PM |
View |
PCD Engineering Division
9/12/2023 1:10:27 PM |
(CDs Part 2 redlined pages) | 9/12/2023 1:10:27 PM |
View |
PCD Engineering Division
9/12/2023 1:09:53 PM |
(CDs Part 1 redlined pages) | 9/12/2023 1:09:53 PM |
View |
PCD Engineering Division
9/12/2023 1:08:42 PM |
(Report redlined pages) | 9/12/2023 1:08:42 PM |
View |
PCD Engineering Division
9/12/2023 1:07:27 PM |
See comment letter (link to left) and redlines. The following items need to be revised and resubmitted: - Channel Drainage Report if model changes, or appendix/memo to address remaining issues. Individual sheets can be swapped out if necessary. - CDs/GEC Plan (3 parts) - Deviation request(s) for channel design attributes (approved) - Other items highlighted in blue on the Engineering checklist need to be provided when available, with signatures where applicable. -- Jeff Rice - 719-520-7877 |
9/12/2023 1:07:27 PM |
EPC Stormwater Review
9/7/2023 12:41:24 PM |
All Stormwater comments have been addressed. Reviewed by: Christina Prete, P.E. Stormwater Engineer III ChristinaPrete@elpasoco.com |
9/7/2023 12:41:24 PM | |
Upper Black Squirrel Creek GWMD
9/6/2023 3:19:22 PM |
The Upper Black Squirrel Creek GWMD does not have any comments at this time but respectfully reserves the right to comment on future submittals. | 9/6/2023 3:19:22 PM | |
PCD Project Manager
8/30/2023 1:13:03 PM |
Defer to engineering. Planning has no comments. | 8/30/2023 1:13:03 PM | |
Colorado Springs Public Works
8/24/2023 1:26:31 PM |
Engineering Development Review has no comment on this item. Joel Dagnillo, P.E. Engineer III Engineering Development Review City of Colorado Springs (719)385-5412 Joel.dagnillo@coloradosprings.gov |
8/24/2023 1:26:31 PM | |
Colorado Springs Public Works
8/21/2023 8:35:38 AM |
Traffic Engineering has no comments on this item. Zaker Alazzeh, P.E. Traffic Engineering Manager/Deputy City Traffic Engineer City of Colorado Springs (719) 385-5468 Zaker.Alazzeh@coloradosprings.gov |
8/21/2023 8:35:38 AM | |
View |
PCD Engineering Division
5/19/2023 3:17:44 PM |
(TimberRidge FDR excerpts) | 5/19/2023 3:17:44 PM |
View |
PCD Engineering Division
5/19/2023 3:17:13 PM |
(Example riffle drop details) | 5/19/2023 3:17:13 PM |
View |
PCD Engineering Division
5/19/2023 3:16:50 PM |
(O&M redline for discussion) | 5/19/2023 3:16:50 PM |
View |
PCD Engineering Division
5/19/2023 3:16:25 PM |
(FAE redlines) | 5/19/2023 3:16:25 PM |
View |
PCD Engineering Division
5/19/2023 3:15:55 PM |
(Structural CD redlined pages for information) | 5/19/2023 3:15:55 PM |
View |
PCD Engineering Division
5/19/2023 3:15:14 PM |
(CD redlines - part 3) | 5/19/2023 3:15:14 PM |
View |
PCD Engineering Division
5/19/2023 3:14:39 PM |
(CD redlines - part 2) | 5/19/2023 3:14:39 PM |
View |
PCD Engineering Division
5/19/2023 3:14:02 PM |
(CD redlines - part 1) | 5/19/2023 3:14:02 PM |
View |
PCD Engineering Division
5/19/2023 3:13:19 PM |
(Design report redlined pages) | 5/19/2023 3:13:19 PM |
View |
PCD Engineering Division
5/19/2023 3:12:40 PM |
See comment letter (link to left) and redlines. The following items need to be revised and resubmitted: - Channel Drainage Report if model changes, or appendix to address remaining issues. Individual sheets can be swapped out if necessary. - CDs/GEC Plan (3 parts) - Deviation request(s) for channel design attributes (approved) - Other items highlighted in blue on the Engineering checklist need to be provided when available, with signatures where applicable. -- Jeff Rice - 719-520-7877 |
5/19/2023 3:12:40 PM |
EPC Stormwater Review
5/18/2023 10:46:11 AM |
EPC Stormwater comments have been addressed. Reviewed by: Christina Prete Stormwater Engineer III christinaprete@elpasoco.com |
5/18/2023 10:46:11 AM | |
View |
PCD Engineering Division
2/21/2023 10:53:43 PM |
(CD redlines sheets 90-111) | 2/21/2023 10:53:43 PM |
View |
PCD Engineering Division
2/21/2023 10:50:57 PM |
(CD redlines sheets1-89) | 2/21/2023 10:50:57 PM |
View |
PCD Engineering Division
2/21/2023 10:15:32 PM |
(PBMP Applicability Form redlines) | 2/21/2023 10:15:32 PM |
View |
PCD Engineering Division
2/21/2023 10:14:53 PM |
(ESQCP redlines) | 2/21/2023 10:14:53 PM |
View |
PCD Engineering Division
2/21/2023 10:14:26 PM |
(Structural CD redlines) | 2/21/2023 10:14:26 PM |
View |
PCD Engineering Division
2/21/2023 10:08:44 PM |
(FDR redlines) | 2/21/2023 10:08:44 PM |
View |
PCD Engineering Division
2/21/2023 10:07:19 PM |
(MDDP redlined page) | 2/21/2023 10:07:19 PM |
View |
PCD Engineering Division
2/21/2023 10:06:50 PM |
See comment letter (link to left) and redlines. The following items need to be revised and resubmitted: - MDDP - Channel Drainage Report - CDs/GEC Plan - Structural CDs - ESQCP - PBMP Applicability Form - Deviation request(s) for channel design attributes - Other items highlighted in blue on the Engineering checklist need to be provided when available, with signatures where applicable. -- Jeff Rice - 719-520-7877 |
2/21/2023 10:06:50 PM |
PCD Project Manager
2/16/2023 7:48:31 AM |
Deviations should be submitted so that design can be finalized with maintenance entity | 2/16/2023 7:48:31 AM | |
EPC Stormwater Review
2/14/2023 5:13:54 PM |
Review 6: EPC Stormwater comments have been provided (in orange text boxes) on the following uploaded documents: - CDs.....................................(to be uploaded by PM with PCD comments) - ESQCP................................(to be uploaded by PM with PCD comments) - PBMP Applicability Form.....(to be uploaded by PM with PCD comments) Please provide the following documents upon resubmittal: - MS4 - O&M - SDI Reviewed by: Christina Prete Stormwater Engineer III christinaprete@elpasoco.com |
2/14/2023 5:13:54 PM | |
View |
PCD Engineering Division
11/1/2022 4:33:36 PM |
(CD/GEC redlines summary) | 11/1/2022 4:33:36 PM |
View |
PCD Engineering Division
11/1/2022 4:32:09 PM |
(CD/GEC redlines) | 11/1/2022 4:32:09 PM |
View |
PCD Engineering Division
11/1/2022 4:21:05 PM |
(FDR redlines summary) | 11/1/2022 4:21:05 PM |
View |
PCD Engineering Division
11/1/2022 4:20:30 PM |
(FDR redlines) | 11/1/2022 4:20:30 PM |
View |
PCD Engineering Division
11/1/2022 4:13:19 PM |
(MDDP redlines summary) | 11/1/2022 4:13:19 PM |
View |
PCD Engineering Division
11/1/2022 4:12:33 PM |
(MDDP redlines) | 11/1/2022 4:12:33 PM |
View |
EPC Stormwater Review
10/31/2022 1:25:17 PM |
PBMP_v5 | 10/31/2022 1:25:17 PM |
View |
EPC Stormwater Review
10/31/2022 1:23:52 PM |
ESQCP_v5 | 10/31/2022 1:23:52 PM |
View |
EPC Stormwater Review
10/31/2022 1:20:27 PM |
GEC Checklist_v5 | 10/31/2022 1:20:27 PM |
View |
EPC Stormwater Review
10/31/2022 1:19:55 PM |
FAE_v5 | 10/31/2022 1:19:55 PM |
EPC Stormwater Review
10/31/2022 1:24:59 PM |
Review 5: EPC Stormwater comments have been provided (in orange text boxes) on the following uploaded documents: - CDs.........................(to be uploaded by PM with PCD comments) - FAE - GEC Checklist - ESQCP - PBMP Applicability Form Please provide the following documents upon resubmittal: - MS4 - O&M - SDI Reviewed by: Christina Prete Stormwater Engineer III christinaprete@elpasoco.com |
10/31/2022 1:24:59 PM | |
View |
PCD Engineering Division
10/19/2022 4:01:27 PM |
See comment letter (link to left) and redlines. The following items need to be revised and resubmitted: - MDDP - Channel Drainage Report - CDs/GEC Plan - Deviation request(s) for channel design attributes - FAE(s) - Other items highlighted in blue on the Engineering checklist need to be provided when available, with signatures where applicable. Redlines will be uploaded once coordination with Stormwater Staff is complete. -- Jeff Rice - 719-520-7877 |
10/19/2022 4:01:27 PM |
PCD Project Manager
10/11/2022 7:42:07 AM |
Please see Engineering Comments | 10/11/2022 7:42:07 AM | |
Colorado Springs Public Works
9/23/2022 1:28:50 PM |
Engineering Development Review has no comment on this item. Joel Dagnillo, P.E. Engineer III Engineering Development Review City of Colorado Springs (719)385-5412 Joel.dagnillo@coloradosprings.gov |
9/23/2022 1:28:50 PM | |
Colorado Springs Public Works
9/20/2022 12:46:21 PM |
Traffic Engineering has no comments on this item. Zaker Alazzeh, P.E. Traffic Engineering Manager/Deputy City Traffic Engineer City of Colorado Springs (719) 385-5468 Zaker.Alazzeh@coloradosprings.gov |
9/20/2022 12:46:21 PM | |
View |
EPC Stormwater Review
5/19/2022 3:03:18 PM |
GEC Checklist_v4 | 5/19/2022 3:03:18 PM |
View |
PCD Engineering Division
5/19/2022 8:44:40 AM |
(Response redlines) | 5/19/2022 8:44:40 AM |
View |
PCD Engineering Division
5/19/2022 8:44:08 AM |
(FAE redlines) | 5/19/2022 8:44:08 AM |
View |
PCD Engineering Division
5/19/2022 8:43:42 AM |
(CD/GEC redlines summary) | 5/19/2022 8:43:42 AM |
View |
PCD Engineering Division
5/19/2022 8:43:03 AM |
(CD/GEC redlines) | 5/19/2022 8:43:03 AM |
View |
PCD Engineering Division
5/19/2022 8:42:09 AM |
(DR redlines summary) | 5/19/2022 8:42:09 AM |
View |
PCD Engineering Division
5/19/2022 8:41:46 AM |
(DR redlines) | 5/19/2022 8:41:46 AM |
View |
PCD Engineering Division
5/19/2022 8:41:09 AM |
(MDDP redlines summary) | 5/19/2022 8:41:09 AM |
View |
PCD Engineering Division
5/19/2022 8:40:48 AM |
(MDDP redlines) | 5/19/2022 8:40:48 AM |
View |
PCD Engineering Division
5/19/2022 8:40:10 AM |
See comment letter (link to left) and redlines. The following items need to be revised and resubmitted: - MDDP - Channel Drainage Report - CDs/GEC Plan - Deviation request for channel design attributes - FAEs - Other items highlighted in blue on the Engineering checklist need to be provided when available, with signatures where applicable. -- Jeff Rice - 719-520-7877 |
5/19/2022 8:40:10 AM |
EPC Stormwater Review
5/19/2022 3:03:46 PM |
Review 4: EPC Stormwater comments have been provided (in orange text boxes) on the following uploaded documents: - CDs.........................(to be uploaded by PM with PCD comments) - FAE.........................(to be uploaded by PM with PCD comments) - GEC Checklist The following submitted documents will be reviewed under subsequent construction filing: - ESQCP - SWMP - SWMP Checklist Reviewed by: Christina Prete Stormwater Engineer III christinaprete@elpasoco.com |
5/19/2022 3:03:46 PM | |
View |
Colorado Parks and Wildlife
5/11/2022 4:53:27 PM |
5/11/2022 4:53:27 PM | |
PCD Project Manager
5/9/2022 9:11:22 AM |
See Engineering comments Please | 5/9/2022 9:11:22 AM | |
View |
Colorado Department of Public Health and Environment
5/4/2022 1:51:06 PM |
Please find CDPHE's standard comments attached | 5/4/2022 1:51:06 PM |
View |
EPC Environmental Services
4/22/2022 11:23:28 AM |
4/22/2022 11:23:28 AM | |
View |
EPC Parks Department
4/21/2022 3:53:40 PM |
El Paso County Community Services / Parks Final Comments, Review #4 - Please See Attached Document for Updated Comments (No PAB Endorsement Necessary - Administrative Comments Only) | 4/21/2022 3:53:40 PM |
Upper Black Squirrel Creek GWMD
4/21/2022 1:57:39 PM |
The Upper Black Squirrel Creek GWMD does not have any comments at this time but respectfully reserves the right to comment on future submittals. | 4/21/2022 1:57:39 PM | |
Colorado Springs Utilities, Dev, Svc.(includes water resources)
4/18/2022 1:19:41 PM |
The proposed construction looks to be outside of the utility easement in the area. It appears like CS utilities is not the only utility in the area, however if the engineer of record or contractor believes there are additional CS utilities in the area, please notify us. If the intended work interfered with CS utilities' gas during construction, please call our gas field engineers at 719-668-4985 ____________________________________________ Corey Masoumi | Engineering Support Coordinator Colorado Springs Utilities | Utilities Development Services PHYSICAL: 1521 S Hancock Expressway, Colorado Springs, CO 80903 Direct (719) 668-1856 | Main (719) 668-8259 |
4/18/2022 1:19:41 PM | |
RBD Floodplain
4/12/2022 4:19:38 PM |
Floodplain is OK with the CLOMR statement on file : "SAND CREEK AT STERLING RANCH Sand Creek Drainageway and Roadway Design CLOMR Statement A Conditional Letter of Map Revision (CLOMR), will be required for this project as the effect of the proposed construction will be to raise, and lower the base flood elevations for Sand Creek within the Sterling Ranch Development from those depicted on FIS panels 533G and 533 G. Floodway limits will also be affected and revised from what now shows on the effective El Paso County Flood Insurance Study, revised December 2018. CLOMR will be submitted to FEMA after the first review by El Paso County Engineering is completed and the once the general lines and grades of the improvements are not subject to change. " |
4/12/2022 4:19:38 PM | |
View |
PCD Engineering Division
12/27/2021 10:06:06 AM |
(CDs/GEC redlines summary) | 12/27/2021 10:06:06 AM |
View |
PCD Engineering Division
12/27/2021 10:05:25 AM |
(CDs/GEC redlines) | 12/27/2021 10:05:25 AM |
View |
PCD Engineering Division
12/27/2021 10:04:51 AM |
(FDR redlines summary) | 12/27/2021 10:04:51 AM |
View |
PCD Engineering Division
12/27/2021 10:04:27 AM |
(FDR redlines) | 12/27/2021 10:04:27 AM |
View |
PCD Engineering Division
12/27/2021 10:04:01 AM |
(MDDP redlines summary) | 12/27/2021 10:04:01 AM |
View |
PCD Engineering Division
12/27/2021 9:25:21 AM |
(MDDP redlines) | 12/27/2021 9:25:21 AM |
View |
PCD Engineering Division
12/27/2021 9:23:49 AM |
See comment letter (link to left) and redlines. The following items need to be revised and resubmitted: - MDDP - Channel Drainage Report - CDs/GEC Plan - Deviation request for channel design attributes - FAEs - Other items highlighted in blue on the Engineering checklist need to be provided when available, with signatures where applicable. -- Jeff Rice - 719-520-7877 |
12/27/2021 9:23:49 AM |
View |
EPC Parks Department
11/23/2021 10:35:33 AM |
El Paso County Community Services / Parks Final Comments, Review #3 - Please See Attached Comments (No PAB Endorsement Necessary) | 11/23/2021 10:35:33 AM |
EPC Stormwater Review
12/13/2021 1:54:34 PM |
Review 3: EPC Stormwater comments have been provided (in orange text boxes) on the following uploaded documents: - CDs.........................(to be uploaded by PM with PCD comments) Please address Stormwater Review 2 comments on the following documents: - ESQCP - SWMP - GEC and SWMP Checklists Reviewed by: Christina Prete Stormwater Engineer III christinaprete@elpasoco.com |
12/13/2021 1:54:34 PM | |
View |
Colorado Parks and Wildlife
11/16/2021 8:50:29 AM |
11/16/2021 8:50:29 AM | |
Colorado Parks and Wildlife
11/11/2021 12:01:20 PM |
CPW submitted a comment letter on July 20, 2020 for this project. After reviewing the portion of this project, CPW believes that the original comments still stand and that comment letter can be referenced for this project. We appreciate being given the opportunity to comment. Please feel free to contact District Wildlife Manager, Aaron Berscheid, should you have any questions or require additional information at 719-439-9601 or via email at aaron.berscheid@state.co.us |
11/11/2021 12:01:20 PM | |
Colorado Springs Utilities, Dev, Svc.(includes water resources)
11/8/2021 12:41:24 PM |
The proposed construction looks to be outside of the utility easement in the area. It appears like CS utilities is not the only utility in the area, however if the engineer of record or contractor believes there are additional CS utilities in the area, please notify us. If the intended work interfered with CS utilities' gas during construction, please call our gas field engineers at 719-668-7858. ____________________________________________ Corey Masoumi | Engineering Support Coordinator Colorado Springs Utilities | Utilities Development Services PHYSICAL: 1521 S Hancock Expressway, Colorado Springs, CO 80903 MAILING: PO BOX 1103, MC 1812, Colorado Springs, CO 80947-0010 Direct (719) 668-1856 | Main (719) 668-8259 www.csu.org • www.csu.org/Pages/BuildingDevelopment.aspx |
11/8/2021 12:41:24 PM | |
View |
EPC Environmental Services
11/4/2021 9:13:57 AM |
11/4/2021 9:13:57 AM | |
Upper Black Squirrel Creek GWMD
11/3/2021 11:13:26 AM |
The Upper Black Squirrel Creek GWMD does not have any comments at this time but respectfully reserves the right to comment in the future if necessary. | 11/3/2021 11:13:26 AM | |
View |
Colorado Department of Public Health and Environment
11/1/2021 11:27:51 AM |
Please see the attached comments. Also, please remove my sean.hackett@state.co.us email from your referral contact list and send all CDPHE referrals to cdphe_localreferral@state.co.us. | 11/1/2021 11:27:51 AM |
RBD Floodplain
10/28/2021 11:17:49 AM |
CLOMR Statement acknowledges the need for an approved CLOMR prior to grading/earthwork permit from the Regional Floodplain office. | 10/28/2021 11:17:49 AM | |
PCD Project Manager
11/20/2020 8:28:28 AM |
Please be prepared to have a meeting with your engineer and PCD Staff to discuss the deviations for the channel design soon. | 11/20/2020 8:28:28 AM | |
View |
PCD Engineering Division
11/19/2020 5:26:08 PM |
(LOI redlines) | 11/19/2020 5:26:08 PM |
View |
PCD Engineering Division
11/19/2020 5:25:40 PM |
(CD-GEC redlines summary) | 11/19/2020 5:25:40 PM |
View |
PCD Engineering Division
11/19/2020 5:25:14 PM |
(CD-GEC redlines) | 11/19/2020 5:25:14 PM |
View |
PCD Engineering Division
11/19/2020 5:24:33 PM |
(FDR redlines summary) | 11/19/2020 5:24:33 PM |
View |
PCD Engineering Division
11/19/2020 5:23:35 PM |
(FDR redlines) | 11/19/2020 5:23:35 PM |
View |
PCD Engineering Division
11/19/2020 5:23:02 PM |
See comment letter and redlines. DO NOT RESUBMIT THE PROJECT without approved deviations or revised design to meet criteria. Discuss with Staff. -- Jeff Rice - 719-520-7877 |
11/19/2020 5:23:02 PM |
View |
EPC Stormwater Review
11/16/2020 5:26:58 PM |
GEC and SWMP Checklists_V2 | 11/16/2020 5:26:58 PM |
View |
EPC Stormwater Review
11/16/2020 5:24:41 PM |
SWMP_V2 | 11/16/2020 5:24:41 PM |
View |
EPC Stormwater Review
11/16/2020 5:23:43 PM |
ESQCP_V2 | 11/16/2020 5:23:43 PM |
EPC Stormwater Review
11/16/2020 2:42:38 PM |
Review 2: Stormwater comments have been provided on the following uploaded documents: - ESQCP - CDs (to be uploaded by the PM) - SWMP - GEC and SWMP Checklists Comments have been resolved on the following documents: - PBMP Applicability Form Reviewed by: Christina Furchak Stormwater Engineer III christinafurchak@elpasoco.com |
11/16/2020 2:42:38 PM | |
View |
PCD Engineering Division
7/22/2020 6:46:09 PM |
(ECM Chapter 6) | 7/22/2020 6:46:09 PM |
View |
PCD Engineering Division
7/22/2020 6:45:34 PM |
(CDR-GEC redlines summary) | 7/22/2020 6:45:34 PM |
View |
PCD Engineering Division
7/22/2020 6:45:03 PM |
(CDR-GEC redlines) | 7/22/2020 6:45:03 PM |
View |
PCD Engineering Division
7/22/2020 6:44:15 PM |
(FDR redlines summary) | 7/22/2020 6:44:15 PM |
View |
PCD Engineering Division
7/22/2020 6:43:44 PM |
(FDR redlines) | 7/22/2020 6:43:44 PM |
View |
PCD Engineering Division
7/22/2020 6:42:56 PM |
(Wetlands redlines) | 7/22/2020 6:42:56 PM |
View |
PCD Engineering Division
7/22/2020 6:42:06 PM |
(LOI redlines) | 7/22/2020 6:42:06 PM |
View |
PCD Engineering Division
7/22/2020 6:40:56 PM |
See comment letter and redlines. | 7/22/2020 6:40:56 PM |
PCD Project Manager
7/15/2020 7:02:51 AM |
Please work with outside agencies to address their comments. | 7/15/2020 7:02:51 AM | |
View |
EPC Parks Department
7/10/2020 3:44:32 PM |
El Paso County Community Services / Parks Final Comments - Please See Attached Documents (No PAB Endorsement Necessary) | 7/10/2020 3:44:32 PM |
Colorado Springs Public Works
7/2/2020 1:56:54 PM |
Engineering Development Review has no comments on this item. | 7/2/2020 1:56:54 PM | |
View |
EPC Stormwater Review
7/2/2020 11:11:31 AM |
Checklists V_1 | 7/2/2020 11:11:31 AM |
View |
EPC Stormwater Review
7/2/2020 11:09:27 AM |
SWMP V_1 | 7/2/2020 11:09:27 AM |
View |
EPC Stormwater Review
7/2/2020 11:07:36 AM |
CD V_1 | 7/2/2020 11:07:36 AM |
View |
EPC Stormwater Review
7/2/2020 11:06:06 AM |
PBMP V_1 | 7/2/2020 11:06:06 AM |
View |
EPC Stormwater Review
7/2/2020 11:03:38 AM |
ESQCP V_1 | 7/2/2020 11:03:38 AM |
EPC Stormwater Review
7/2/2020 11:01:23 AM |
Review 1: Stormwater comments have been provided on the following uploaded documents: - ESQCP - PBMP - CD - SWMP - GEC and SWMP Checklists Reviewed by: Christina Furchak Stormwater Engineer III christinafurchak@elpasoco.com |
7/2/2020 11:01:23 AM | |
View |
Colorado Department of Public Health and Environment
7/2/2020 8:59:13 AM |
7/2/2020 8:59:13 AM | |
Colorado Springs Public Works
7/2/2020 8:43:24 AM |
General Reminder - plans/ reports approved by the County will be required to be reapproved by the City should annexation occur prior to the completion of the project. The proposed longitudinal slopes are too steep, based on City criteria, the max slopes would be 0.17% (DCM Volume 1, Ch. 12 Figure 12-4). If this is stricter than County Criteria, it is recommended to follow City Criteria. Maximum drop height should not exceed 4ft (DCM Vol 1 Ch 12 Table 12-7). The project summary states the maximum drop height is 7ft and the plans show drops up to 9ft. The max velocity should not exceed 7fps as stated in the project summary, the HEC RAS model shows several areas exceeding 7fps in between drops. Anna Bergmark Stormwater Enterprise City of Colorado Springs 30 S. Nevada Ave., Suite 401 Colorado Springs, CO 80901 (719) 385-5613 office (719) 619-9427 Cell Anna.Bergmark@coloradosprings.gov |
7/2/2020 8:43:24 AM | |
View |
EPC Environmental Services
6/24/2020 2:03:36 PM |
6/24/2020 2:03:36 PM | |
Colorado Springs Public Works
6/17/2020 7:44:16 AM |
Traffic Engineering has no comments on this item. Zaker Alazzeh, P.E. Traffic Engineering Manager City of Colorado Springs (719) 385-5468 Zaker.Alazzeh@coloradosprings.gov |
6/17/2020 7:44:16 AM | |
Upper Black Squirrel Creek GWMD
6/16/2020 12:46:31 PM |
The Upper Black Squirrel Creek GWMD does not have any comments at this time but reserves the right to comment in the future. | 6/16/2020 12:46:31 PM | |
Colorado Springs Utilities, Dev, Svc.(includes water resources)
6/15/2020 2:49:38 PM |
Colorado Springs Utilities does not provide reviews for CDR's. -Kyle Schelhaas, 719-668-8126, kschelhaas@csu.org |
6/15/2020 2:49:38 PM | |
RBD Floodplain
6/12/2020 11:25:57 AM |
this project will be permitted through regional floodplain once the FEMA CLOMR has been approved. | 6/12/2020 11:25:57 AM |