Link Agency Comment
EPC County Attorney's Office
8/8/2019 1:10:14 PM
No comments and no further review required unless Planner advises differently. Any easements or other conveyances of property interests will require CAO review and approval. Cole Emmons 8/8/19 8/8/2019 1:10:14 PM
View Colorado Division of Water Resources
8/5/2019 4:56:47 PM
8/5/2019 4:56:47 PM
PCD Engineering Division
8/5/2019 4:49:12 PM
Engineering documents have been accepted for file.

Engineering has no additional comments.
8/5/2019 4:49:12 PM
EPC Health Department
7/16/2019 11:55:26 AM
Please see comments submitted 03Apr2019. Mike McCarthy 7/16/2019 11:55:26 AM
View PCD Engineering Division
7/11/2019 2:27:04 PM
Comment provided by Elizabeth Nijkamp, 719-520-7852

A deviation has been approved for the placement of the water line within the public ROW to be at a depth of 4' instead of the EPC criteria which states 5' depth, and shall be uploaded by the project manager. Note that vertical separation on all lines shall meet Federal and State regulations.

Please submit an ESQCP (attached)
Please submit WQ deviations per conservations between Brock Hodgson and Elizabeth Nijkamp.
7/11/2019 2:27:04 PM
PCD Project Manager
6/18/2019 10:10:31 AM
Note: please keep in mind that when an item is uploaded, it will replace the previous item in EDARP.

1. The following items have not been submitted to date:
-Traffic control plan
-O&M
-Site development plan with all property lines, structures, easements, setbacks, etc.
-access easement agreement
-action and prevention plan

We will need to review these items prior to the closeout of the project.
6/18/2019 10:10:31 AM
View Parks Advisory Board
6/14/2019 1:53:34 PM
El Paso County Community Services / Parks Final Comments - Please See Attached Documents 6/14/2019 1:53:34 PM
View PCD Engineering Division
6/10/2019 5:43:34 PM
On the GEC, update the signature blocks to include the names of those signing and update the notes to the current 27 Standard GEC notes (please see attachment)

In the construction drawings refer to ECM Chapter 4, Section 4.3.6.A.1 Water Lines. "At no time shall water service lines be placed less than 5 feet in depth measured perpendicularly to the ground line, at any point of the road cross section, to the right-of-way line."

Approval of the construction drawings is contingent upon adherence to ECM Section 4.3.6.A.1 Water Lines. Please show and call out a minimum of 5 foot cover within public Right of Way for all water lines.

Once this item has been resolved, please submit all engineering documents with PE Seal and signature for approval.

Thank you,

Beck Grimm
6/10/2019 5:43:34 PM
View EPC Environmental Services
6/4/2019 9:33:59 AM
6/4/2019 9:33:59 AM
PCD Project Manager
5/13/2019 6:36:13 AM
Previous comments still remain.

EPC needs confirmation if you will receive an exemption of the MS4 permit requirements or if you will fall under the EPC MS4 permit.
5/13/2019 6:36:13 AM
View Parks Advisory Board
5/9/2019 1:29:52 PM
El Paso County Community Services / Parks Final Comments, Review #2 (Please see attached documents) 5/9/2019 1:29:52 PM
View PCD Engineering Division
5/7/2019 4:58:06 PM
In the construction drawings refer to ECM Chapter 4, Section 4.3.6.A.1 Water Lines. "At no time shall water service lines be placed less than 5 feet in depth measured perpendicularly to the ground line, at any point of the road cross section, to the right-of-way line."

Please see attached the checklist for the Grading and Erosion Control Plan and Stormwater Management Plan. Items on the lists that are highlighted must be addressed. Highlighted items which are not applicable to this project must be noted in the respective plan accordingly.

On the GEC, update the signature blocks to include the names of those signing and update the notes to the current 27 Standard GEC notes as shown in the checklist attachment.

Review 1 comments still apply to the following documents:
-Easement
-Natural Features

In the drainage report, identify the Four Step Process. This can be found in the Engineering Criteria Manual, Appendix I, Section I.7.2 BMP Selection.
5/7/2019 4:58:06 PM
Pikes Peak Regional Building Department
5/7/2019 2:26:22 PM
No further comment. 5/7/2019 2:26:22 PM
View EPC Health Department
5/1/2019 4:46:14 PM
See 03Apr2019 comments submitted. 5/1/2019 4:46:14 PM
View EPC Environmental Services
4/25/2019 11:58:15 AM
4/25/2019 11:58:15 AM
Fountain
4/9/2019 10:32:22 AM
No impacts to City of Fountain roadways. 4/9/2019 10:32:22 AM
View Parks Advisory Board
4/4/2019 10:01:33 AM
El Paso County Community Services / Parks Final Comments - Please see attached document (No PAB endorsement necessary - administrative comments only) 4/4/2019 10:01:33 AM
View EPC Health Department
4/3/2019 11:35:43 AM
4/3/2019 11:35:43 AM
View PCD Project Manager
3/28/2019 8:09:03 AM
Alternative Redlines 3/28/2019 8:09:03 AM
View PCD Project Manager
3/28/2019 8:08:45 AM
CDPHE Redlines 3/28/2019 8:08:45 AM
View PCD Project Manager
3/28/2019 8:08:27 AM
PPR Redlines 3/28/2019 8:08:27 AM
View PCD Project Manager
3/28/2019 8:08:13 AM
Schedule Redlines 3/28/2019 8:08:13 AM
View PCD Project Manager
3/28/2019 8:07:57 AM
Natural Features Redlines 3/28/2019 8:07:57 AM
View PCD Project Manager
3/28/2019 8:07:31 AM
SWMP Redlines 3/28/2019 8:07:31 AM
View PCD Project Manager
3/28/2019 8:07:14 AM
Traffic Redlines 3/28/2019 8:07:14 AM
View PCD Project Manager
3/28/2019 8:06:59 AM
GEC Redlines 3/28/2019 8:06:59 AM
View PCD Project Manager
3/28/2019 8:06:44 AM
Easement Redlines 3/28/2019 8:06:44 AM
View PCD Project Manager
3/28/2019 8:06:23 AM
CD Redlines 3/28/2019 8:06:23 AM
View PCD Project Manager
3/28/2019 8:06:01 AM
Drainage Redlines 3/28/2019 8:06:01 AM
PCD Engineering Division
3/27/2019 2:13:08 PM
Engineering comments can be found on the following documents, which will be uploaded by the project manager:
-Drainage Plan
-GEC
-SWMP
-Easement
-CD
-Natural Features
-PPR
-Traffic
3/27/2019 2:13:08 PM
PCD Project Manager
3/26/2019 3:44:41 PM
We understand that this is a CERCLA project and that precludes the County from requiring any permits or approvals. We understand that we are acting as a review agency for the project to simply identify any large discrepancies in what is being proposed in comparison to our regulations.

1. Numerous items were not submitted but instead we have been told they will be provided for review at a later date. Please be aware that due to them not being provided we cannot provide you with any substantive comments regarding these items. Please submit the remaining requested items as soon as possible.
2. The proposed project may impact private property. Please coordinate with the private property owners for the work adjacent to and on their property.
3/26/2019 3:44:41 PM
Pikes Peak Regional Building Department
3/26/2019 2:57:41 PM
1. Please provide a site plan of the entire lot zoomed in, with all proposed structures and equipment.
2. Address assigned 4140 Lincoln Plaza Drive.
3. Floodplain has no comment.
3/26/2019 2:57:41 PM
View Colorado Department of Public Health and Environment
3/26/2019 9:53:29 AM
3/26/2019 9:53:29 AM
View EPC Environmental Services
3/22/2019 12:32:12 PM
3/22/2019 12:32:12 PM